14 xL Simplified Installation Guide
21-3601E rev1.3
Areas A02 – A16 undefined
A01 Defaults Press Ok to Edit
Area Name Area Entry
Delay
Select a time.
Area Exit
Delay
Select a time.
Exit Delay Mode
Normal
Warning Tone Short, Warning
Tone Long, Warn & Block
(Warning Tone & Block Arming).
Fail to Exit Mode
Door Close, Push
Button, Both, None
Default: OFFICE
(UK ACPO = “AREA
DESCRIP”)
Default:
45 Seconds
(UK ACPO = 30 sec)
Default:
60 Seconds
Default: Normal
(UK ACPO = Warn & Block)
Default: Door Close
(UK ACPO = Push Button)
STAY on Fail to
Exit
Alarm on Fail to
Exit
Exit Delay on Fail to
Exit
Area Report Mode
Selections:
Full, Emergency
Bell Squawk
None, On Arming, Fail
to Arm, Both.
Default: No Default: No
(UK ACPO = Yes)
Default: No
(UK ACPO = Yes)
Default: Emergency Default: None
(UK ACPO = Fail to Arm)
Modules M01 – M24
M01 Defaults, M02 – M24 undefined.
Module Serial #
Enter the 5 digit number from the
sticker on the module’s circuit board.
NOTE: When “ÈOk” is pressed after
entering the Serial #, you may be
transferred out of programming.
Return to Module Programming to
continue programming the module.
Module Type
I/O = input / output
Selections: Use the left and right arrow keys to browse the module names.
Keypad:
LCDV2, LCD Plus, LCD-GProx, LCD-ExtRd (external reader),
Wireless:
WLS, FA400, EE4000,
HSC
Power:
IPSU 1.1AMP
Vigil
Other
Access:
Regular V2, Regular V1, TDC, PDC, C2000, IPlus, 2050MIL250,
2050DC,
I/O:
Regular, E-I/O, IPMUX, 2050IO16, 2050I32, 2050O32
Elevator
Suite Security:
Suite 8 zone, Suite 2 zone
Default: 00000
Default: LCD-GProx
Number of Inputs
Selections: 00, 04,
08, 12, 16, 20, 24,
32
Number of Outputs
Selections: 00, 04,
08, 12, 16, 20, 24, 32
Module in Area?
Assign the module to the
area it is in.
Tamper Monitor
Exit Delay Level
Stay & On, On
Only, None
Default:
08 inputs
Default:
04 outputs
Default:
A01: OFFICE
(UK ACPO = “AREA DESCRIP”)
Default:
Yes
Default:
Stay & On
Tone Warnings
Yes/No
Default:
Yes
Annunciate Area
Map
(KeyPad tones)
Press the button below “ÈEdit “ to make changes. Scroll through the areas at the top of the
screen using the left and right keypad arrows. When an area appears that needs to cause
this keypad in this area to annunciate tones for e.g. alerts, exit tones from the other area,
press the keypad button below ÈYes or ÈNo to assign the other area(s) to this keypad. A
check mark
9will appear beside the Yes or No selection. Default: 9(Yes) for Area 1