HSC-IP Module Installation Instructions
9 / 2008
© 2008 CSG Security Inc. / Sécurité CSG Inc. Page 5 of 13
Guardall (formerly VEREX Technology)
5201 Explorer Drive, Mississauga, Ont., Canada. L4W-4H1
sales@verextech.com +1 905.206.8434 | support@verextech.com +1 905.206.8436 | Fax: +1 905.629.4970
www.guardall.com | +1 877.249.9993
Version 3 IP Module to Version 4 HSC-IP Module Upgrade Utility
After locating the Upgrade Utility executable on the Director Software disk, double click on it to install it. After the upgrade
utility and version 4 HSC-IP Module firmware included with the utility have been installed, open the utility by double
clicking on it. The following screen will appear:
Connection
Target
The version 3 IP Module can be connected to in 2 ways with the Upgrade Utility:
Discover the IP Module
Follow the instructions for “Using the Discovery Feature” in Step 8, “HSC-IP Module Programming Utility”
Connect Remotely
The IP address of the version 3 IP Module must be known. It can be obtained from the Director Software that has been
communicating with it in “Configuration/System/Communication”. Enter the version 3 IP Module’s IP address in the IP
Address box and the IP Module’s Password if it has one.
Press the “Connect” button at the top of the screen. The upgrade utility will attempt to connect with the version 3 IP
Module over the same network that the IP module is on.
If the connection fails, the “Abort” button will be enabled. Press the Abort button to re-enable “Connect” and try again or
check network connections, try pinging the IP address from the start/run/open:cmd prompt to check if it is responding.
Also check “Key Information” next to Connection on the Utility screen. Is there a message like “Invalid Key”? If so, the
license key may need replacement. Contact the supplier.
Module Information
If a successful connection has been made to the version 3 IP Module, the “Disconnect”, “Upgrade” and “Force” buttons
will be enabled. The module’s current MAC address, firmware number, program file name, protocol or identifying name (IP
Address) will display. This information will change when the firmware has been upgraded.
While in communication with the version 3 IP Module for upgrading, press the “Upgrade” button. A dialogue box will open
that has located the firmware on the PC and displays its file name and version to upgrade the version 3 IP Module to the
version 4 HSC-IP module. Acknowledge the dialogue box to load the upgrade to version 4 firmware to the version 3 IP
Module. Watch the activity messages in the lower, left corner of the utility screen as an aid to know what is happening
between the utility and the IP module. Dialogue will appear there while the IP Module’s firmware is being upgraded and
will indicate when the upgrade is finished.
If there seems to be difficulty attempting to upgrade using the ‘Upgrade” button, try using the “Force” button to perform the
upgrade.
The “About” button will display details for the upgrade software.
When the upgrade is completed, press the “Disconnect” button to stop communications with the IP Module. The IP
Module should now be a version 4 HSC-IP Module and ready to connect to with the HSC-IP Module Configuration Utility
for configuring it to communicate with the HSC-IP Receiver and Director Software. Proceed to Step 8, “Security System’s
HSC-IP Module Programming with Utility”.